Backyard Science Calculators Tools › Science calculators हिंदी

Dilution calculator (C1V1 = C2V2) and molarity calculator

Solve any of C1, V1, C2 or V2 with a different unit on every line, see exactly how much stock and diluent to pipette, work out grams to weigh for a molar solution, or plan a serial dilution — for labs, school practicals and home experiments.

This tool is paused for maintenance. The guide below is still available.

Your numbers

Calculator
g/mol
Needed only when one side is molar (M, mM…) and the other is mass (mg/mL, %, ppm).

Everything runs in your browser. Nothing you type is sent anywhere.

Results

Answer—
—
—

How to make it

    The dilution equation: C1V1 = C2V2

    Diluting a solution adds solvent but never adds or removes solute. The amount of solute you take out of the stock bottle is exactly the amount that ends up in the new container, so concentration multiplied by volume is the same before and after:

    C1 × V1 = C2 × V2

    SymbolMeaningTypical units
    C1Concentration of the stock solutionM, mM, mg/mL, %, 10X
    V1Volume of stock you takemL, µL
    C2Concentration you want after dilutingsame kind as C1
    V2Total final volume (stock + diluent)mL, L

    Rearranged, the most common question — how much stock do I need? — is V1 = C2 × V2 ÷ C1. The diluent you add is V2 − V1, and the dilution factor is C1 ÷ C2. When the concentrations are molarities, the same equation is often written M1V1 = M2V2.

    Worked examples (these are automated tests of this page)

    • Cell culture: you have a 10 mM stock and need 10 mL at 100 µM. Convert to the same unit: 10 mM = 10,000 µM. V1 = 100 µM × 10 mL ÷ 10,000 µM = 0.1 mL = 100 µL of stock plus 9.9 mL of medium — a 1:100 dilution.
    • Classic lab problem: how much 10 mM stock makes 20 mL of 50 µM? V1 = 50 × 20 ÷ 10,000 = 0.1 mL = 100 µL.
    • Percent: 50 mL of 70% isopropyl alcohol made up to 100 mL gives C2 = 70 × 50 ÷ 100 = 35%.
    • Molarity prep: 250 mL of 0.5 M sodium chloride (58.44 g/mol) needs 0.5 × 0.250 × 58.44 = 7.305 g of NaCl.

    Mixing units without mistakes

    The calculator converts every line separately, so you can type the stock in mM, the target in µM and the volume in mL. The rules it uses:

    • Molar units step by 1,000: 1 M = 1,000 mM = 1,000,000 µM = 10⁹ nM.
    • Mass units: 1 g/L = 1 mg/mL = 1,000 µg/mL; 1 mg/L = 1 ppm for dilute aqueous solutions.
    • Percent is treated as weight per volume (w/v): 1% = 1 g per 100 mL = 10 mg/mL. If both C1 and C2 are percentages the factor cancels, so volume-per-volume solutions such as ethanol or isopropanol work too.
    • Converting between molar and mass units needs the molar mass: mg/mL = mM × g/mol ÷ 1,000. Enter it in the molar-mass box and the calculator does the rest.
    • Fold units (10X, 5X buffers) can only be diluted to another X value: 50 mL of 10X buffer made up to 500 mL gives 1X.

    Molarity: how much to weigh

    Molarity (amount concentration) is moles of solute per litre of solution — not per litre of water added. To prepare a solution of known molarity:

    mass (g) = molarity (mol/L) × volume (L) × molar mass (g/mol)

    Choose a compound from the list to fill in its molar mass, or type your own. For hydrated salts use the molar mass of the hydrate you actually weigh — copper sulfate pentahydrate (CuSO₄·5H₂O, 249.69 g/mol) needs far more grams than anhydrous CuSO₄ (159.61 g/mol) for the same molarity. If your reagent is 98% pure, enter 98 in the purity box and the mass is increased so that the solution still contains the intended amount of solute. Always dissolve in less solvent than the final volume, then make up to the mark in a volumetric flask: dissolving a solid changes the volume, so "add 7.3 g to 250 mL of water" gives a slightly different concentration than "make up to 250 mL".

    Serial dilutions

    When you need a very weak solution, or a series of standards for a calibration curve, one big dilution is inaccurate because the stock volume becomes tiny. A serial dilution repeats a modest dilution several times. For a 1:10 series with 1 mL in each tube, put 0.9 mL of diluent in every tube, add 0.1 mL (100 µL) of the starting solution to the first, mix, transfer 100 µL to the next, and so on. After six steps the concentration has fallen by a factor of 10⁶. The serial mode works out the transfer and diluent volumes and lists the concentration of every tube. Typical uses are microbiology plate counts, ELISA standards, and school experiments on how food colouring fades with dilution.

    Accuracy tips

    • Pick a sensible V1. Pipetting less than about 2 µL is unreliable on most pipettes; if the calculator gives a tiny V1, make an intermediate dilution first or use the serial mode.
    • Use volumetric glassware for V2, and a calibrated micropipette or graduated pipette for V1. Measuring cylinders are fine for rough school work.
    • Add acid to water, never water to acid. Diluting concentrated sulfuric or hydrochloric acid releases heat; pour the acid slowly into the water with stirring, wearing goggles and gloves.
    • Temperature matters a little. Volumes change with temperature, so make standards at room temperature.
    • Label everything with the concentration, solvent, date and your initials.

    Five mistakes the calculator catches

    1. Mismatched units. Typing 10 for a 10 mM stock and 100 for a 100 µM target without converting gives an answer 1,000 times too large. Each line here has its own unit menu, so the conversion is automatic.
    2. Using V2 as the volume of water. V2 is the total final volume, not the diluent. The diluent is V2 − V1, shown separately.
    3. Asking a dilution to concentrate. If C2 is larger than C1, no amount of mixing will work; the calculator warns you instead of returning a negative volume.
    4. Mixing molar and mass units without a molar mass. mM and mg/mL can only be compared through the molar mass, so the page asks for it.
    5. Forgetting the water of crystallisation. Weighing a hydrate with the anhydrous molar mass gives a weaker solution than intended; choose the hydrate from the list.

    Where this is useful at home and at school

    Beyond the lab bench, the same arithmetic is used to dilute fertiliser concentrates for plants, sodium hypochlorite bleach for disinfecting surfaces (follow the label's ratio), hand-sanitiser isopropyl alcohol from 99% to about 70%, and sugar or salt solutions for osmosis experiments in Class 9–12 practicals. The equation is part of the NCERT Class 12 chemistry unit on solutions, and the worked examples here match the textbook method step by step.

    Frequently asked questions

    How do I calculate a dilution?

    Use C1V1 = C2V2. To find the stock volume, V1 = C2 × V2 ÷ C1, with both concentrations in the same unit. Then add V2 − V1 of diluent.

    How much 10 mM stock do I need for 10 mL of 100 µM?

    10 mM is 10,000 µM, so V1 = 100 × 10 mL ÷ 10,000 = 0.1 mL, i.e. 100 µL of stock plus 9.9 mL of diluent (a 1:100 dilution).

    How do I make a 0.5 M NaCl solution?

    Mass = 0.5 mol/L × volume in litres × 58.44 g/mol. For 250 mL that is 7.305 g, dissolved and made up to 250 mL in a volumetric flask.

    Can I mix units such as mM and mg/mL?

    Yes, if you enter the molar mass. mg/mL = mM × molar mass ÷ 1,000. Percent is treated as w/v (1% = 10 mg/mL).

    What is a dilution factor?

    The ratio of stock to final concentration, C1 ÷ C2. A factor of 100 is written 1:100 — one part stock in 100 parts total.

    What is a serial dilution?

    A series of equal dilutions, each made from the previous tube. Ten-fold steps reduce the concentration 10, 100, 1,000 times and so on.

    Sources

    Formulas and molar masses checked on 18 November 2026 against LibreTexts, NCERT and PubChem.

    More tools

    For education and routine lab preparation. Follow your institution's safety rules and the reagent's safety data sheet; this page is not a substitute for a validated laboratory protocol.