Why “1.5-ton AC units per hour” is really a watts question
Indian summer search is full of the phrase “1.5 ton AC electricity consumption per hour”. The honest answer is that a cooling ton is not an electrical unit. One ton of refrigeration is a cooling rate, historically 12,000 BTU per hour, about 3.517 kW of heat moved. The electricity the compressor and fans draw at the socket is a smaller, different number, set by the machine’s efficiency and by how hard the room is working it. A modern 1.5-ton split may draw around 1,200 to 1,800 watts when the compressor is on; older or poorly serviced machines can sit higher. This page therefore starts from input watts, with a 1,500 W default for a typical 1.5-ton unit that you can overwrite the moment you have a nameplate or a plug-meter reading.
Once input power is in kilowatts, units are straightforward: units per hour = kW, because 1 unit is 1 kWh. A 1,500-watt input uses 1.5 units in one full hour, 12 units in eight full hours, and 360 units in a 30-day month if it really ran eight hours a day at that draw. Real rooms are kinder than that. The compressor cycles off when the thermostat is satisfied, so monthly units are often lower than this “always-on at nameplate” figure. Use the result as a planning ceiling, then compare a week of meter readings if you want a tighter number. For the difference between kW and kWh itself, see the electricity unit calculator. For a rupee estimate with fans, geysers and a fridge as well, use the bijli bill tool.
How to pick the watt figure
Look for “input power” or “power supply” on the indoor or outdoor sticker, not for “cooling capacity” in tons or BTU. Inverter ACs also change their draw as they ramp, so a single watt number is already a simplification. If you have an energy-star or ISEER label, it describes a seasonal efficiency, not a constant wattage. This calculator does not invent an ISEER-to-watts conversion, because that would hide the assumption. Type the watts you trust, or leave the 1,500 W starting point and treat the output as “if it were a 1.5 kW load”.
The existing AC tonnage calculator on this site answers a different question: how much cooling a room might need. This page answers what that machine might cost in units once you already have it, or once you are comparing two nameplates. Do not mix the two. Oversizing a room and then running a large compressor on short cycles can use more electricity than a correctly sized unit that runs smoothly. Tonnage and units are related through design, not through a single magic constant.
Worked examples
1. Default 1,500 W, one hour: 1.50 units. 2. The same machine for eight hours: 12.00 units in a day, and 360.00 units over 30 such days if the compressor never eased off. 3. A more efficient 1,200 W 1-ton preset for eight hours: 9.60 units a day. 4. A 1,800 W 2-ton preset for eight hours: 14.40 units a day. Change hours or watts and the three totals move together, so you can see whether cutting two afternoon hours is worth more than shaving 200 W off the input.
This is not a BEE test report, not a DISCOM tariff, and not a promise that your bill will fall by a stated percentage if you buy a new star rating. It is a transparent units-per-hour and units-per-month estimate from the electrical input you provide. For rupees, type those units into the bill calculator with your own rate or slab. Official licensee pages remain the place for published tariffs. Keep filters clean, set a reasonable temperature, and close the obvious sun-facing gaps — those habits change the hours the compressor must work, which is often the larger lever once the watts are fixed.