Wire Size CalculatorA free tool on thebackyardscientist.com

Wire size calculator – copper cable from watts (single-phase)

Watts, 230 V aur cable ki length daaliye. Current, 1.25 margin, ek simple copper size aur approximate voltage drop dikhte hain. Yeh electrician ki design ki jagah nahi leta.

Cable / wire size from load (single-phase, copper)

Current ratings below are typical clipped-direct copper PVC figures used in Indian domestic estimating (about 15 / 20 / 27 / 35 / 46 / 62 A for 1.5 / 2.5 / 4 / 6 / 10 / 16 mm²). They are not a substitute for the cable maker’s table or an electrician’s design.

From watts to a copper wire size you can talk about

Household cable sizing starts with current. In single-phase power, current in amperes is watts divided by (voltage × power factor). At the default 2,000 W geyser on 230 V with a power factor of 1, I = 2000 ÷ 230 = 8.70 A. This page then multiplies by 1.25 to leave a simple margin (10.87 A) and picks the smallest copper size in a short domestic table whose current ratings are at least that design current: 1.5 mm² ~ 15 A, 2.5 mm² ~ 20 A, 4 mm² ~ 27 A, 6 mm² ~ 35 A, 10 mm² ~ 46 A, 16 mm² ~ 62 A. For the geyser, 1.5 mm² would carry the current on paper, but many Indian houses still run geysers and ACs on 2.5 mm² or 4 mm² because of length, grouping and future load — which is why the card also prints a voltage-drop sketch.

Voltage drop

A long, thin cable wastes volts as heat. A common estimating formula for single-phase go-and-return drop is 2 × I × L × r / 1,000, where L is the one-way length in metres and r is resistance in ohms per kilometre. Using about 12.1 Ω/km for 1.5 mm² copper, a 15 m run at 8.70 A drops 2 × 8.70 × 15 × 12.1 / 1000 = 3.16 V, about 1.4% of 230 V. That is usually acceptable. The same current on a 40 m run would be closer to 3.6% and might push you up a size. The resistances used here are typical annealed-copper figures; your cable’s data sheet wins if it disagrees.

Load at 230 VCurrentSmallest table size after ×1.25
1,000 W4.35 A1.5 mm²
2,000 W (default)8.70 A1.5 mm²
3,000 W13.04 A2.5 mm²

Hindi mein

2,000 वाट, 230 वोल्ट: 8.70 एम्पीयर। 1.25 का मार्जिन लगाने पर 10.87 एम्पीयर, इस घरेलू तालिका में 1.5 मिमी² काफी है। लंबी लाइन पर वोल्टेज ड्रॉप देखें — 15 मीटर पर लगभग 3.2 वोल्ट। यह इलेक्ट्रीशियन की डिज़ाइन नहीं है।

What this page refuses to pretend

It does not know how many circuits share a conduit, how hot the roof void is, or whether the load is a motor that starts at several times its running current. Those factors live in IS 3961 / manufacturer tables and in an electrician’s judgement. Treat the suggestion as a way to understand a quotation, not as permission to rewire a house from a webpage. For LED lighting circuits 1.5 mm² is common; for 1.5-ton AC points many electricians prefer 2.5 or 4 mm² regardless of the tidy 6–7 A running current, because of starting current and future replacement machines.

How to use

  1. Type the watts of one circuit, not the whole house, unless you really mean the incomer.
  2. Leave 230 V unless you measured something else.
  3. Set length as the one-way run from the board to the point.
  4. Read current, suggested size and voltage drop, then confirm with an electrician and the cable maker’s table.

I = P / (V × pf) is the single-phase power identity. The current-rating column is a simplified clipped-copper domestic set for estimating, aligned with common Indian site tables, not a full copy of any one manufacturer’s chart. Voltage-drop resistances are typical copper Ω/km values. Follow IS wiring practice and a licensed electrician for anything that will be energised.

A 1.5-ton AC example

A 1.5-ton air-conditioner may run around 1,200–1,800 W. At 1,500 W the current is 6.52 A, and the table would allow 1.5 mm² after the 1.25 margin. Many electricians still pull 2.5 mm² or 4 mm² to that point because the compressor’s starting current is several times higher and because the next owner may install a larger machine on the same wires. The calculator will not override that habit; it will only show you the running-current arithmetic so you understand the quotation.

Frequently asked questions

2000 W par kaun sa wire?

About 8.70 A at 230 V; after a 1.25 margin this table still allows 1.5 mm², but many houses use 2.5 mm² on geyser points.

Voltage drop kaise?

2 × I × L × Ω/km ÷ 1000 for go-and-return.

1.25 kyun?

A simple extra margin on this page, not a full diversity calculation.

Aluminium?

Not in this table. Ratings would change.

Whole house?

Size each circuit, then talk to an electrician about the incomer.

AC point?

Often wired thicker than the running-current table suggests, because of starting current.

An estimating sketch using a short domestic copper table. Not a substitute for IS tables, grouping factors or a licensed electrician.